Phone: +34 938 272 932
WEBDOM DATALOGGER 1.5
Webdom Datalogger 1.5

Monitoring and Control

of the Photovoltaic Plant

Webdom Datalogger 1.5 is perfect for monitoring and remote control of photovoltaic systems greater than 100kW.

Webdom Datalogger 1.5
In the box

1x Webdom Datalogger 1.5

1x Soporte Carril DIN

1x Soporte Pared

Power Supply Connector

User Manual

General

Certifications

Dimensions

Enclosure

Power Input Range

Mounting

Power Consumption

Power Requirement

Weight

CE, FCC Class A, CCC, UL

50 x 154 x 127 mm. Important tips for the right box size: minimum width 196mm.

Aluminium with solid mounting hardware

Dual 10 ~ 30 VDC inputs with reserve power polarity

DIN35 rail, wall

6 W (Typical)

10 ~ 30 VDC (e.g. + 24 VDC @ 1 A) (Min. 24 W), AT

450g

General

Certifications

CE, FCC Class A, CCC, UL

Dimensions

50 x 154 x 127 mm. Important tips for the right box size: minimum width 196mm.

Enclosure

Aluminium with solid mounting hardware

Power Input Range

Dual 10 ~ 30 VDC inputs with reserve power polarity

Mounting

DIN35 rail, wall

Power Consumption

6 W (Typical)

Power Requirement

10 ~ 30 VDC (e.g. + 24 VDC @ 1 A) (Min. 24 W), AT

Weight

450g

System Hardware

CPU

Memory

VGA

Indicators

Storage

Others

TI Cortex A8 AM3505 600 MHz

256 MB DDR2

THS8136 controller, DB-15 VGA Connector

Power, Serial (Tx, Rx), SD, 4 x DI, 2 x DO, 4 Programmable LEDs

2 SD slots

Real Time Clock, Watch Dog Timer

System Hardware

CPU

TI Cortex A8 AM3505 600 MHz

Memory

256 MB DDR2

VGA

THS8136 controller, DB-15 VGA Connector

Indicators

Power, Serial (Tx, Rx), SD, 4 x DI, 2 x DO, 4 Programmable LEDs

Storage

2 SD slots

Others

Real Time Clock, Watch Dog Timer

System Software

OS

Remote Display

WinCE .NET 6.0 / Embedded Linux

DiagAnywhere Utility (Windows CE only)

System Software

OS

WinCE .NET 6.0 / Embedded Linux

Remote Display

DiagAnywhere Utility (Windows CE only)

Communication

Serial Ports

 

Serial Port Speed

1 x RS-485, 4 x RS-232/422/485 (COM1 ~ COM5)

Automatic RS-485 data flow control

RS-232: 300 ~ 115.2 kbps

RS-422/485: 300 ~ 115.2 kbps

LAN: 2 x 10/100 Base-T RJ-45 ports

Communication

Serial Ports

1 x RS-485, 4 x RS-232/422/485 (COM1 ~ COM5)

 

Automatic RS-485 data flow control

Serial Port Speed

RS-232: 300 ~ 115.2 kbps

RS-422/485: 300 ~ 115.2 kbps

Digital I/O

Digital In

 

 

Digital Out

4 Digital Input

Dry Contact: Logic level 0: Open, Logic level 1: Close

2 Digital Output

Open Collect to 30V

200mA max Load

Power Dissipation 450mW

Digital I/O

Digital In

4 Digital Input

 

Dry Contact: Logic level 0: Open, Logic level 1: Close

 

2 Digital Output

Digital Out

Open Collect to 30V

200mA max Load

Environment

Operating Temperature

Safety Cert. Temperature

Storage Temperature

Operating Humidity

Storage Humidity

-10 ~ 70°C (14° ~ 158°F)

6070

-20° ~ 80°C (-4° ~ 176°F)

20 ~ 95% (non-condensing)

0 ~ 95% (non-condensing)

Environment

Operating Temperature

-10 ~ 70°C (14° ~ 158°F)

Safety Cert. Temperature

6070

Storage Temperature

-20° ~ 80°C (-4° ~ 176°F)

Operating Humidity

20 ~ 95% (non-condensing)

Storage Humidity

0 ~ 95% (non-condensing)

Frequently Asked Questions
Answers to frequently asked questions associated with Webdom Datalogger 1.5
El Webdom Datalogger 1.5 dispone de un total de 5 puertos serie, de los cuales, 4 son configurables RS232/422/485 (mediante DIP-SWITCH), y presentan un conector DB-9 macho. Existe un quinto puerto RS485 en un bornero (terminal de bloques atornillable) en la parte inferior del datalogger. Internamente implementa los protocolos de comunicaciones de distintos fabricantes (ver lista completa), como inversores fotovoltaicos, Combiner Boxes, contadores digitales de compañía eléctrica, sensores meteorológicos, y en definitiva, cualquier dispositivo que implemente un protocolo de comunicaciones compatible RS232/422/485, cuyo protocolo sea de dominio público y lo podamos implementar. Cualquier dispositivo compatible con el estándar Modbus puede ser conectado a este equipo, implementando las direcciones Modbus correspondientes. Modbus-RTU es compatible con el puerto RS485, Modbus-TCP es compatible con el puerto Ethernet. El protocolo RS232 es un protocolo punto a punto que solo permite conectar un dispositivo en un mismo puerto. El cable que interconecta ambos puntos no puede ser muy largo (menos de 10 metros). Por el contrario, el protocolo RS422/485 permite interconectar múltiples dispositivos en un mismo bus, y alcanzar distancias teóricas de hasta 1200 metros). Cada dispositivo debe identificarse con una dirección única de bus (normalmente los dispositivos disponen de un DIP-SWITCH o interruptor que permite seleccionar su dirección), de 0-255.
Es muy importante utilizar un cable de comunicaciones apantallado (por ejemplo, manguera Li-2YCYv 2x2x0.5). La pantalla debe estar debidamente conectada a tierras, solo en uno de los dos extremos del cable, para evitar el problema del bucle de tierras (Grounding Loops). No confundir la pantalla con la línea de referencia GND, que debe estar conectada en la entrada correspondiente del terminal de bloques del datalogger. La velocidad de transmisión de datos ayuda a minimizar los problemas de interferencias, o sea, mejor trabajar a 9.6kbps que a 115.2kbps.
Por defecto, los puertos serie de comunicaciones del datalogger no están aislados. Esta característica puede estar incluida bajo pedido, pudiendo aislar los puertos que sean necesarios por separado.
El datalogger accede de forma periódica a un servidor horario de internet, y actualiza la hora interna del sistema operativo, proporcionando de esta forma unos valores muy fiables y precisos.